276°
Posted 20 hours ago

Talon - Click in Pipe Collar - White - 110mm - for Soil/Vent Pipes - Simple Click Together System - for Home Improvement, Plumbing, Pipe Installation - Tool Set Essentials

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

When installing a QuelCast Manifold Recess Former to the underside of the slab the process is: cut the spigot off the manifold, position the QuelCast on the manifold within the indentations, secure together using self tapping screws through each corner of the QuelCast body and then install as a whole unit using the centre line indicators on the Manifold Recess Former as a guide instead of the QuelCast. The Quelfire QWR CE Marked Fire Collars consist of a continuous pressed stainless steel flexible shell containing high performance graphite based intumescent material which reacts under the influence of heat to exert pressure on the pipe as it softens to form a carbonaceous char which provides an effective insulation plug thus preventing smoke and fire passing through to the adjoining compartment. The QWR CE Marked Fire Collar has built in fixing lugs which are used to secure it to the structure. The QWR CE Marked Fire Collars consist of a continuous pressed stainless steel flexible shell containing high performance graphite based intumescent material which reacts under the influence of heat to exert pressure on the pipe as it softens to form a carbonaceous char which provides an effective insulation plug thus preventing smoke and fire passing through to the adjoining compartment.

The QuelCast Manifold has been designed and developed to create a 70 mm recess in the floor slab either on the top or on the bottom of the floor slab to allow for applications where there is limited ceiling space and so the plastic pipe can be installed closer to the ceiling with the pipe connection recessed in the slab. For example: Our extensive range of Pipe Collars supports the wide and diverse nature of projects that Talon customers are working on and as an experienced business, we understand many of the common challenges that customer’s face regularly, which allows us to provide innovative and problem-solving solutions. Tested on a plasterboard ceiling/timber floor in accordance with the principles of BS EN1366-3:2009 This 110mm pipe collar will seal flammable pipes 110mm diameter and can be face fixed in a wall or ceiling structure. They are suitable for use on concrete, masonry and plasterboard partitions for up to 240 minutes. The above information is based on current test data, health and safety information and application instructions supplied by our suppliers and manufacturers of the products. It is supplied for guidance and to the best of our knowledge is true and accurate. Customers should satisfy themselves to the suitability of the products in its intendeduse and no guarantee is given or impliedas the conditions of actual use are beyond our control. If in doubt the customer should consult the designerof the project or the local building control.With decades of experience in the supply of pipe collars, our ISO accreditation, and 24-hour production, Talon has become the market leading provider of piping products and accessories in the UK, as well as to customers around the world. Tested to Type X durability which means the QWR Fire Collars can be installed in conditions exposed to weathering. QWR CE Marked Fire Collars are expected to last the lifetime of the building.

Talon’s approach to quality applies to our products, processes, people and partners. Our quality management policy has been designed to support the company’s strategic objectives and is implemented within the framework of internationally recognised, standardised management systems”. When the intumescent collar has been securely fitted into place any residual gaps between the intumescent collar and the substrate can be filled using Pyroplex® Intumescent Acrylic Sealant. The QWR CE Marked Fire Collar has built in fixing lugs which are used to secure it to the structure, and can be used in conjunction with QF2 Fire Protection Compound.

QuelCast Manifold Recess Former

Tested to Type X durability which means the QWR Fire Collars can be installed in conditions exposed to weathering. Quelfire QWR CE Marked Fire Collars are expected to last the lifetime of the building. All of our products are manufactured in-house and by a team of experts, allowing us to provide consistent quality control and efficient service for every single customer. Talon is an ISO 9001 Quality Assured business and our approach focuses on providing a top quality service to deliver top quality products. We also provide a trusted export service to customers around the globe - find out more about Talon exporting or get in touch for more information.

We pride ourselves on our approach to building long-term relationships with customers to become a valued supplier and accommodating specific customer requirements where possible as well as furthering our company-wide commitment to reducing our carbon footprint. Secure intumescent 110mm pipe collar by drilling holes in structure by using fixing lugs as template. To fix use M8 x 65mm sleeve anchors or 50mm [minimum] expanding bolts.Unfortunately we, Insulation Express, cannot deliver to the Highlands & Islands of the UK. However we will be happy to deliver to a freight forwarding company on your behalf.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment