About this deal

The Honeywell valves have a D-shaped top to the spindle but you can also use a spanner on this. If you do this, you must use very little force as it is very easy to shear a spindle or damage the valve internally. Synchron valve motors can remain energised and hot for many hours a day, all through the winter. They may eventually fail. A failed Synchron valve motor will prevent a 2-port motorised valve from working. The valve won’t be driven open and the end switch will not be made (connected) so power will not be sent on to the boiler or pump. If the powerhead (actuator) can be safely removed from the valve body (see warning above about pre-1985 Honeywell valves) you can try to turn the spindle. You may need a tool unless you have strong fingers. You must also isolate the electrical supply before removing a Honeywell motorised valve powerhead. The V4043 series of 2 port Motorised Valves has a wide range of flow control applications in domestic and light commercial central heating systems. The V4043H normally closed models have end switches for electrical control of pump and/or boiler. The V4043B normally open model is particularly applicable to control of solid fuel systems, since it will always fail-safe in the event of a power failure.

The V4043B valves are uncommon and likely to be found in solid fuel systems. These valves fail-safe in the open position in the event of a power failure or valve motor failure. Honeywell V4073A1039 22mm 3-port mid-position motorised valve showing inlet port AB and outlet ports A and B. This valve can be open to either port A or port B, or to both ports at the same time V4043H1007 is a 2 port, ¾” BSP Female threaded, 5-wire, normally-closed zone valve with an auxiliary end switchV4043H1056 is a 2 port, 22mm compression, 5-wire, normally-closed zone valve with an auxiliary end switch On older style valves pre-1985, which do not have the replaceable head feature, the adaptor plate assembly can be used to upgrade the valves, to allow the replaceable powerhead to be used.”

Both of these genuine SYNCHRON motors work in Honeywell motorised valves. The motors SYNCHRON make specifically for Honeywell come with two blue wires A Switchmaster Midi 3-port valve body with a seized spindle. This motorised valve was also rusting through round the screw in the picture Honeywell powerhead (actuator) jams? Crimps are metal tubes within plastic insulation, which are flattened using pliers to trap two wires, joining them electrically. These crimps can sometimes be re-opened by using pliers to squeeze together the edges of the flattened tube. This can be done with the plastic in place. If successful it frees the two wires. The plastic insulation may break, in which case the crimp is discarded. System boilers may also have a diverter valve or zone valve built into them and might not have any external zone valves.If you know how to work safely with mains voltage electricity, the valve motor can be tested with a multimeter. With the mains electrical supply turned off and isolated, the resistance across the two motor wires (either both blue or both orange) can be tested. To test correctly, at least one of the two motor wires must be disconnected from the heating wiring circuit. The commonest fault with Honeywell motorised valves is motor failure. Honeywell valve motor fault? Testing a Synchron valve motor V4043H1106 is a 2 port, 28mm compression, 6-wire, normally-closed zone valve with an auxiliary end switch Sometimes a powerhead is able to drive the valve only part way open but not far enough for the auxiliary circuit end switch to close. This valve will then not be able to tell the boiler to fire.

A normally-open valve is open when no power is being applied to it and needs electrical power to drive it closed. Honeywell V4043h 1056 2 Port Motorised Zone Valve 22mm V4043h1056 Specialists In Plumbing Heating Spares X Honeywell V4043h 1056 2 Port Motorised Zone Valve 22mm V4043h1056 Specialists In Plumbing Heating Spares

Why Use The Engineer Scheme?

Before beginning the installation process, it is important to read and understand the Honeywell V4043H wiring diagrams thoroughly. Once this has been done, the installer should: