Glycerol Monostearate (GMS) is a commonly used additive (although other similar chemicals are also used), which is introduced during the extrusion phase of the material manufacture.

Some fire-resistant foams are specifically designed and tested to fill larger gaps. Closely follow the conditions of use stated in the certification if installing a fire-rated foam product One of the best known fire rated foams on the market is the Blue 60 Foam , which is blue instead of pink, but has the same non-combustible qualities as pink foam. There are life safety implications – use the foam correctly and in the right situations to achieve conformity with the Building Regulations. Disappointed. Didn’t realise the laces weren’t real laces and were instead stitched in elastic… they’re ‘laced’ in a pattern I don’t like and you can’t make the entrance wide enough for the feet to go in easily enough. Complete waste of money to be fair, taken them to a charity shop in the box

What is Intumescent Material?

This foam sheet is just one colour available in our range of foam sheets. This versatile craft material is ideal for a number of creative projects, such as toy-making, papercrafts, school projects and plenty more creative ideas! You can add texture and colour in an instant! If there's been a COSHH Assessment for the product, the relating document should advise on how to safely remove it. PU foams are combustible and generally will only offer fire-stopping properties when used in narrow voids or gaps Manufactured to include an anti-static additive, these pink foams give a surface conductivity that will reduce over time.

Evolutions Fire Protection are Third-Party Certified Fire Stopping specialists under the Q-Mark BMTRADA scheme. Polyurethane (PU) foam fillers - also known as ‘fire foam’ - are common in construction, but if you use them without properly understanding them they can end up costing you money, creating worse fire risks, and potentially ruin your hard-earned reputation.A common mistake is for fire rated foam to be used in situations where intumescent sealant is better suited. Fire foams are usually tinted pink to distinguish them from other non-fire rated foams, but they’re all different and have varying functions and properties - make sure you’re using the right one. It is recommended by ASFP, BMTRADA, FIRAS, IFE that any installations of pink foam are removed and replaced with a true fire rated alternative due to it being difficult to trace the product without chemical composition testing.

Pink anti-static foam’s unique properties allow the foam to slowly dissipate electro-static charges that are potentially created by adjacent components, the component itself or even human handlers during the transit process. Fire rated foam is not suitable for use around pipe and cables as it doesn’t intumesce or expand in extreme heat so the services would burn away and leave a void and thus breach the fire compartment. Sign up to stay on top of the latest fire safety regulations and specifications, and be one of the first to hear about our latest news and offers. In addition the PU Foams can affect the dielectric constant of data cabling. Chemical ingress can change the dielectric constant of a cable thus causing a change in the impedance value and causing failures in data transmission. However the change in the dielectric constant may not show up immediately but could occur in a longer time frame. This can be due to the hydroscopic nature of PVC and LSZH cable which can cause a capillary action of the Chemical within the cable. This additive will then slowly migrate to the edges of the foam before forming lines on the surface.

Fire Safety Guide For Loft Conversions

Depending on the product and conditions of the fire it can also produce toxic fumes causing permanent health damage. Expanding Foams are not an intumescent, it cannot close or crush a plastic pipe and should never be installed as such. Fire rated foam is often misused due to poor understanding of its suitability. It is important to note that it should only be used to fill small linear gaps, gaps between a door frame and wall and small holes in fire walls. As it is non-combustible, it won’t catch fire and therefore won’t contribute to the spread of fire through a building. Intumescent sealant, on the other hand, does not expand when applied, and only swells up when a fire has broken out and it reaches a certain temperature. In this circumstance, the sealant will then expand and seal a hole to reinstate a wall or door’s fire containment properties.

Fire foams are usually tinted pink to distinguish them from other foam products but they're not all the same - read the instructions Try not to use them at all. Take care to cut and install fire protection so that it fits exactly. Use proper collars and seals if compartments need to be penetrated. While fire rated foam expands on application, it sets hard and will not expand further and seal up a hole when a fire breaks out.This type of foam typically has a volume resistivity in the range of 10 10 – 10 12 ohms.cms and often has a surface resistivity that is higher still. When pink foam has been used on a timber structure the results will bf foams in timber structure the results will be un achieve satisfactory fire-resistant results. One end of the microscopic anti-static molecule protrudes from the material edge and draws in moisture from the ambient air to allow a conductive path for current to pass through.