A cb designed for Pollution Level 2 conditions would not be suitable for harsh outdoor or humid applications that require Pollution Level 3. And it is wrong to use MCB’s dedicated for domestic applications (60898) in industrial applications installations. in BS 7671 indicate that the maximum Z s values in those tables should not be exceeded when the line conductors are at the appropriate maximum permitted temperature (70 o C for thermoplastic). These are all Type 2 circuit breakers and their fault current rating can be determined by the infill paint in the operating handle. to about 10 seconds,current over 200A will disconnect legally - I just cant understand how 200A and my PSC reading of 767A on the shower circuit will disconnect at the same time (is this white MAGIC or am i missing the point).

Some manufacturers state that their cbs with a short-circuit capacity of say, 10 kA comply with BS EN 60898-1 and the same cb with a short-circuit capacity of 15 kA complies with BS EN 60947-2. That's quite a large difference and hence the reason why the national standards in other European countries do not include Zs tables, only the formula is provided.

When this is not carried out, there is a probability that, in the event of an accident, fire or other damage, the installer would be accountable under Health and Safety Legislation. Manufacturers warn against installing circuit- breakers of one manufacturer as replacements for cbs of another manufacturer, without the necessary verification of performance. Or what if the maximum tabulated Z s value in BS 7671, or the OSG or GN 3 needs to be corrected due to ambient temperature? But it is not really a sudden step in risk between 230v and 231, more of a gentle rise in risk from quite safe at about 50V to really very bad for you by perhaps 1500V , from which 2 handy values have been converted into safe times for the table. But the BS EN 60947-2 standard prescribes an instantaneous tripping release which may be provided with a plus or minus 20% tolerance and adjustable as illustrated in Fig.The NICEIC just say refer to manufacturer, but I cant find the information for 60947-3 mcb’s starting from 2A and also for a lot of the motor starters GV2,3 etc etc. There is also one observation that Icu values of MCB’s as per IEC60947 are higher than Icn values of MCB as per IEC60898. does state that the permissible Zs can be calculated and in my opinion it is the best method to ensure that we are not failing Zs values that are still low enough to achieve the required disconnect time. In other words – in the final distribution electrical switchboards of buildings in which the nominal current does not exceed 125A. A frequent enquiry Stroma Certification receives is regarding the maximum values of earth loop impedance (Z s) for legacy circuit breakers manufactured to BS 3871.

They are used to protect power distribution circuits up to 1,000 V AC and 1500 V DC with current ratings of 0. Those basic tech specs alone tell us just how different the use of circuit breakers (CBs) are as defined by the two standards. They use ‘miniature’ circuit-breakers (cbs), moulded case circuit -breakers (MCCBs) and air circuit- breakers (ACBs). For a cable having thermoplastic insulation with a maximum permitted temperature of 70°C, this adjustment can be made by simply multiplying the maximum Z s values in the appropriate table by 0. Circuit-breakers to BS-EN 60947-2 are frequently used for industrial applications in utilities and manufacturing industries.I would also suggest that if your U0 is not subject to the +10% tolerance then disconnection times as per Table 41. The most suitable solution is for MCBs that are certified by both IEC standards since their performance meets requirements for use in residential installations and is high enough for use in industry and infrastructure applications. Dear Mostafa, in IEC 898-1 it is mainly used definition of Icn (rated (nominal) breaking capacity) but not Icu (ultimate breaking capacity) and it makes the difference. RCD as a term used without any further additional information would revert to the most commonly used general purpose version when quoting tripping times.